Supply voltage | 11 | 28 | V | |
Supply current | Supply voltage 12v | 30 | 40 | mA |
Supply voltage 24v | 30 | 40 | mA | |
NMEA in/out | ||||
Input voltage tolerance | Continuous operation | -15 | +15 | V |
Differential input voltage | Required level for data to be detected | 2.0 | - | V |
Output current | RS485 / RS422 compatible | - | 10 | mA |
Baud rate | 4800 | - | bps | |
Data output rate | - | 1 | sec | |
Depth | Sensor dependent (Configurable Cal) | |||
Range (narrow beam) | Airmar P66, P79, < 10 knots, ideal conditions | 0.3 | 200 | metres |
Range (wide beam) | Airmar DT800, < 10 knots, ideal conditions | 0.5 | 150 | metres |
Range (narrow beam) | Airmar P66, P79, 10-40 knots, ideal conditions | 0.3 | 100 | metres |
Range (wide beam) | Airmar DT800, 10-40 knots, ideal conditions | 0.5 | 100 | metres |
Speed | Sensor dependent (Configurable Cal) | |||
Range | Airmar P66, DST800, calibrated 5 Hz / knot | 0.5 | 50 | knots |
Temperature | Sensor dependent (Configurable Cal) | |||
Range | Airmar, calibrated 10k @ 25 °C | -10 | 50 | °C |
General | ||||
Gland clamping range | Cable diameters accommodated | 4.5 | 10 | mm |
Ambient temperature | -20 | +70 | °C |